pymodbus.repl.client package¶
Repl client.
Submodules¶
pymodbus.repl.client.completer module¶
Command Completion for pymodbus REPL.
-
class
pymodbus.repl.client.completer.CmdCompleter(client=None, commands=None, ignore_case=True)¶ Bases:
prompt_toolkit.completion.base.CompleterCompleter for Pymodbus REPL.
-
arg_completions(words, word_before_cursor)¶ Generate arguments completions based on the input.
- Parameters
words – The input text broken into word tokens.
word_before_cursor – The current word before the cursor, which might be one or more blank spaces.
- Returns
A list of completions.
-
property
command_names¶ Return command names.
-
property
commands¶ Return commands.
-
completing_arg(words, word_before_cursor)¶ Determine if we are currently completing an argument.
- Parameters
words – The input text broken into word tokens.
word_before_cursor – The current word before the cursor, which might be one or more blank spaces.
- Returns
Specifies whether we are currently completing an arg.
-
completing_command(words, word_before_cursor)¶ Determine if we are dealing with supported command.
- Parameters
words – Input text broken in to word tokens.
word_before_cursor – The current word before the cursor, which might be one or more blank spaces.
- Returns
-
get_completions(document, complete_event)¶ Get completions for the current scope.
- Parameters
document – An instance of prompt_toolkit.Document.
complete_event – (Unused).
- Returns
Yields an instance of prompt_toolkit.completion.Completion.
-
word_matches(word, word_before_cursor)¶ Match the word and word before cursor.
- Parameters
word – The input text broken into word tokens.
word_before_cursor – The current word before the cursor, which might be one or more blank spaces.
- Returns
True if matched.
-
pymodbus.repl.client.helper module¶
Helper Module for REPL actions.
-
class
pymodbus.repl.client.helper.Command(name, signature, doc, unit=False)¶ Bases:
objectClass representing Commands to be consumed by Completer.
-
create_completion()¶ Create command completion meta data.
- Returns
-
get_completion()¶ Get a list of completions.
- Returns
-
get_meta(cmd)¶ Get Meta info of a given command.
- Parameters
cmd – Name of command.
- Returns
Dict containing meta info.
-
-
class
pymodbus.repl.client.helper.Result(result)¶ Bases:
objectRepresent result command.
-
data= None¶
-
decode(formatters, byte_order='big', word_order='big')¶ Decode the register response to known formatters.
- Parameters
formatters – int8/16/32/64, uint8/16/32/64, float32/64
byte_order – little/big
word_order – little/big
-
function_code= None¶
-
print_result(data=None)¶ Print result object pretty.
- Parameters
data – Data to be printed.
-
raw()¶ Return raw result dict.
-
-
pymodbus.repl.client.helper.get_commands(client)¶ Retrieve all required methods and attributes.
Of a client object and convert it to commands.
- Parameters
client – Modbus Client object.
- Returns
pymodbus.repl.client.main module¶
Pymodbus REPL Entry point.
-
class
pymodbus.repl.client.main.CaseInsenstiveChoice(choices, case_sensitive=True)¶ Bases:
click.types.ChoiceDo case Insensitive choice for click commands and options.
-
convert(value, param, ctx)¶ Convert args to uppercase for evaluation.
-
-
class
pymodbus.repl.client.main.NumericChoice(choices, typ)¶ Bases:
click.types.ChoiceDo numeric choice for click arguments and options.
-
convert(value, param, ctx)¶ Convert.
-
-
pymodbus.repl.client.main.bottom_toolbar()¶ Do console toolbar.
- Returns
-
pymodbus.repl.client.main.cli(client)¶ Run client definition.
pymodbus.repl.client.mclient module¶
Modbus Clients to be used with REPL.
-
class
pymodbus.repl.client.mclient.ExtendedRequestSupport¶ Bases:
objectExtended request support.
-
change_ascii_input_delimiter(data=0, **kwargs)¶ Change message delimiter for future requests.
- Parameters
data – New delimiter character
kwargs –
- Returns
-
clear_counters(data=0, **kwargs)¶ Clear all counters and diag registers.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
clear_overrun_count(data=0, **kwargs)¶ Clear over run counter.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
force_listen_only_mode(data=0, **kwargs)¶ Force addressed remote device to its Listen Only Mode.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
get_clear_modbus_plus(data=0, **kwargs)¶ Get/clear stats of remote modbus plus device.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
get_com_event_counter(**kwargs)¶ Read status word and an event count.
From the remote device”s communication event counter.
- Parameters
kwargs –
- Returns
-
get_com_event_log(**kwargs)¶ Read status word.
Event count, message count, and a field of event bytes from the remote device.
- Parameters
kwargs –
- Returns
-
mask_write_register(address=0, and_mask=65535, or_mask=0, unit=0, **kwargs)¶ Mask content of holding register at address with and_mask and or_mask.
- Parameters
address – Reference address of register
and_mask – And Mask
or_mask – OR Mask
unit – Modbus slave unit ID
kwargs –
- Returns
-
read_coils(address, count=1, slave=0, **kwargs)¶ Read count coils from a given slave starting at address.
- Parameters
address – The starting address to read from
count – The number of coils to read
slave – Modbus slave unit ID
kwargs –
- Returns
List of register values
-
read_device_information(read_code=None, object_id=0, **kwargs)¶ Read the identification and additional information of remote slave.
- Parameters
read_code – Read Device ID code (0x01/0x02/0x03/0x04)
object_id – Identification of the first object to obtain.
kwargs –
- Returns
-
read_discrete_inputs(address, count=1, slave=0, **kwargs)¶ Read count number of discrete inputs starting at offset address.
- Parameters
address – The starting address to read from
count – The number of coils to read
slave – Modbus slave unit ID
kwargs –
- Returns
List of bits
-
read_exception_status(**kwargs)¶ Read tcontents of eight Exception Status output.
In a remote device.
- Parameters
kwargs –
- Returns
-
read_holding_registers(address, count=1, slave=0, **kwargs)¶ Read count number of holding registers starting at address.
- Parameters
address – starting register offset to read from
count – Number of registers to read
slave – Modbus slave unit ID
kwargs –
- Returns
-
read_input_registers(address, count=1, slave=0, **kwargs)¶ Read count number of input registers starting at address.
- Parameters
address – starting register offset to read from to
count – Number of registers to read
slave – Modbus slave unit ID
kwargs –
- Returns
-
readwrite_registers(read_address, read_count, write_address, write_registers, unit=0, **kwargs)¶ Read read_count number of holding registers.
Starting at read_address and write write_registers starting at write_address.
- Parameters
read_address – register offset to read from
read_count – Number of registers to read
write_address – register offset to write to
write_registers – List of register values to write (comma separated)
unit – Modbus slave unit ID
kwargs –
- Returns
-
report_slave_id(unit=0, **kwargs)¶ Report information about remote slave ID.
- Parameters
unit – Modbus slave unit ID
kwargs –
- Returns
-
restart_comm_option(toggle=False, **kwargs)¶ Initialize and restart remote devices.
Serial interface and clear all of its communications event counters.
- Parameters
toggle – Toggle Status [ON(0xff00)/OFF(0x0000]
kwargs –
- Returns
-
return_bus_com_error_count(data=0, **kwargs)¶ Return count of CRC errors received by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_bus_exception_error_count(data=0, **kwargs)¶ Return count of Modbus exceptions returned by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_bus_message_count(data=0, **kwargs)¶ Return count of message detected on bus by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_diagnostic_register(data=0, **kwargs)¶ Read 16-bit diagnostic register.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_iop_overrun_count(data=0, **kwargs)¶ Return count of iop overrun errors by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_query_data(message=0, **kwargs)¶ Loop back data sent in response.
- Parameters
message – Message to be looped back
kwargs –
- Returns
-
return_slave_bus_char_overrun_count(data=0, **kwargs)¶ Return count of messages not handled.
By remote slave due to character overrun condition.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_slave_busy_count(data=0, **kwargs)¶ Return count of server busy exceptions sent by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_slave_message_count(data=0, **kwargs)¶ Return count of messages addressed to remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_slave_no_ack_count(data=0, **kwargs)¶ Return count of NO ACK exceptions sent by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
return_slave_no_response_count(data=0, **kwargs)¶ Return count of No responses by remote slave.
- Parameters
data – Data field (0x0000)
kwargs –
- Returns
-
write_coil(address, value, slave=0, **kwargs)¶ Write value to coil at address.
- Parameters
address – coil offset to write to
value – bit value to write
slave – Modbus slave unit ID
kwargs –
- Returns
-
write_coils(address, values, slave=0, **kwargs)¶ Write value to coil at address.
- Parameters
address – coil offset to write to
values – list of bit values to write (comma separated)
slave – Modbus slave unit ID
kwargs –
- Returns
-
write_register(address, value, slave=0, **kwargs)¶ Write value to register at address.
- Parameters
address – register offset to write to
value – register value to write
slave – Modbus slave unit ID
kwargs –
- Returns
-
write_registers(address, values, slave=0, **kwargs)¶ Write list of values to registers starting at address.
- Parameters
address – register offset to write to
values – list of register value to write (comma separated)
slave – Modbus slave unit ID
kwargs –
- Returns
-
-
class
pymodbus.repl.client.mclient.ModbusSerialClient(framer, **kwargs)¶ Bases:
pymodbus.repl.client.mclient.ExtendedRequestSupport,pymodbus.client.serial.ModbusSerialClientModbus serial client.
-
get_baudrate()¶ Get serial Port baudrate.
- Returns
Current baudrate
-
get_bytesize()¶ Get number of data bits.
- Returns
Current bytesize
-
get_parity()¶ Enable Parity Checking.
- Returns
Current parity setting
-
get_port()¶ Get serial Port.
- Returns
Current Serial port
-
get_serial_settings()¶ Get Current Serial port settings.
- Returns
Current Serial settings as dict.
-
get_stopbits()¶ Get number of stop bits.
- Returns
Current Stop bits
-
get_timeout()¶ Get serial Port Read timeout.
- Returns
Current read imeout.
-
set_baudrate(value)¶ Set baudrate setter.
- Parameters
value – <supported baudrate>
-
set_bytesize(value)¶ Set Byte size.
- Parameters
value – Possible values (5, 6, 7, 8)
-
set_parity(value)¶ Set parity Setter.
- Parameters
value – Possible values (“N”, “E”, “O”, “M”, “S”)
-
set_port(value)¶ Set serial Port setter.
- Parameters
value – New port
-
set_stopbits(value)¶ Set stop bit.
- Parameters
value – Possible values (1, 1.5, 2)
-
set_timeout(value)¶ Read timeout setter.
- Parameters
value – Read Timeout in seconds
-
-
class
pymodbus.repl.client.mclient.ModbusTcpClient(**kwargs)¶ Bases:
pymodbus.repl.client.mclient.ExtendedRequestSupport,pymodbus.client.tcp.ModbusTcpClientTCP client.
-
pymodbus.repl.client.mclient.handle_brodcast(func)¶ Handle broadcast.
-
pymodbus.repl.client.mclient.make_response_dict(resp)¶ Make response dict.