   TThhee SSttoorrmmeerr VViissccoommeetteerr DDaattaa

   AArrgguummeennttss::

   Viscosity: Viscosity of fluid

         Wt: Actuating weight

       Time: Time taken

   SSUUMMMMAARRYY::

        The stormer viscometer measures the viscosity of a
        fluid by measuring the time taken for an inner cylinder
        in the mechanism to perform a fixed number of revolu-
        tions in response to an actuating weight.  The viscome-
        ter is calibrated by measuring the time taken with
        varying weights while the mechanism is suspended in
        fluids of accurately known viscosity.  The data comes
        from such a calibration, and theoretical considerations
        suggest a nonlinear relationship between time, weight
        and viscosity, of the form `Time = (B1*Viscos-
        ity)/(Weight - B2) + E' where `B1' and `B2' are unknown
        parameters to be estimated, and `E' is error.

   DDAATTAA DDEESSCCRRIIPPTTIIOONN::

        The data frame contains the following components:

   SSOOUURRCCEE::

        E. J. Williams (1959) Regression Analysis.  Wiley.